Introduction
This control box is a supporting product of the coal mine safety electric control system. It can be used at various locations such as the entrance of the coal mine, underground mining and excavation work sites, central power distribution rooms, and water pump rooms.
Appearance
Size: 540mm×375mm×185mm
Weight: 30kg
Main Technical Parameters
1. Rated supply voltage: two circuits; single-phase AC127V
2. Input apparent power: ≤1500VA
3. Branch output: Single-phase AC127V/10A (applicable to flameproof control boxes, displays, power supplies, and other equipment)
4. Communication signal interface (intrinsically safe)
a) Transmission mode: RS485
b) Number of interfaces: 1 channel
c) Transmission rate: 9600bps
d) Maximum transmission distance: 100m